Models Available
| Models | Output Voltage | Input Range | Battery Voltage | Charge Current | Max Output Power | Buy |
|---|---|---|---|---|---|---|
| INVC5048H | 230VAC | 180-270VAC (2) | 48V | 20A/35A (3) |
5000VA 4200W (1) |
NOTES: (1) Inverter section front panel programmable to 220/230/240VAC.
(2) Can be programmed to operate from 100-270VAC from front panel (generator mode).
(3) Programmable from front panel.
(2) Can be programmed to operate from 100-270VAC from front panel (generator mode).
(3) Programmable from front panel.
Features and Options
| Wide Range AC Input |
| Up to 5kVA or 4200W Output Power |
| 10kVA Peak Load |
| Fast 10mS Transfer Time |
| 3 Stage (CC/CV/Float) 30A Charger |
| Charger Power Factor >0.95 |
Safety Standards
| UL60950-1 |
| CSA22.2, No. 60950-1 |
| EN60950-1 |
Warranty
| Two Years |
Input Specifications
| AC Nominal Voltage: | 230VAC |
| Voltage Range: | Normal range - 180-270VAC Generator Mode (Wide Range) - 100-270VAC |
| Current: | 30A max. @ 230VAC |
| Frequency: | 47-63Hz |
| Battery | |
| Nominal Voltage: | 48VDC |
| Current: | 60A max. |
| UV Alarm: | 42VDC ±1.2VDC |
| UV Shut-Down: | 40VDC ±1.2VDC |
Output Specifications
| Continuous Power: | 5000VA/4200W |
| Maximum Peak Power: | 10,000VA |
| Motor Load: | 2.5HP |
| Voltage (Inverter): | 220/230/240VAC |
| Voltage Regulation (Inverter): | ±10% |
| Frequency: | 50Hz or 60Hz |
| Frequency Regulation (Inverter): | ±0.1Hz |
| Overload Capacity: | 110-150% - 10s 150-200% - 5s |
| Output Waveform: | Pure Sinewave |
| Transfer Time: | AC to DC - 10ms Typical DC to AC - 20ms Typical |
| Efficiency: | AC to DC (Bypass) - >95% DC to AC (Inverter) - >90% |
| Protection: | Overload, Over Temperature |
Physical Specifications
| Case Material: | Steel |
| Dimensions, Inches (mm): | 4.3 H x 16.0 W x 13.8 D (110 x 407 x 350) |
| Weight: | 19.8 lbs. (9kg.) |
Environmental Specifications
| Operating Temp. Range: | 0ºC to +45ºC |
| Storage Temp. Range: | -20ºC to +70ºC |
| Humidity: | 0% to 95%, Non-Condensing |
| Cooling: | Integral Fans |